× NPS 1/2 NPS 3/4 NPS 1 NPS 1.1/4 NPS 1.1/2  ▸ NPS 2 NPS 2.1/2

Dimensions Socket Weld Flanges & Stud Bolts ASME B16.5

Socket Weld flange
OTHER DIA NPS 2 ID=62.0 F=17.5
CLass 150 300 600 900 1500 2500
DIA A 78 84 84 ... 105 ...
DIA D 150 165 165 ... 215 ...
THK B 19.1 22.3 31.8 ... 44.5 ...
DIA G 91.9 91.9 91.9 ... 91.9 ...
DIA K 120.7 127 127 ... 165.1 ...
H 25.6 33.6 43.4 ... 63.4 ...
NO. L 4 8 8 ... 8 ...
DIA L 19.1 19.1 19.1 ... 25.4 ...
Stud Bolts Diameter x Length
DIA (in) 5/8 5/8 5/8 ... 7/8 ...
 lgth (mm 85 90 110 ... 145 ...

Notes..

  • Dimensions are in millimeters unless otherwise indicated.
  • The length of the Stud Bolt does not include the height of the chamfers (points).
  • ID2 = Depending on the wall thickness of the pipe, must be specified by the purchaser.
  • Important! please read this short article

Dimensional Tolerances of Socket Weld Flanges ASME B16.5
Outside Diameter *
Tolerances not listed in ASME B16.5 2013
≤ 24 = 1.6 mm
> 24 = ± 3.2 mm
Inside Diameter
≤ 10 = ± 0.8 mm
≥ 12 = + 1.6 mm / - 0 mm
Outside Diameter of Hub
≤ 12 = + 2.4 mm / - 1.6 mm
≥ 14 = ± 3.2 mm
Diameter of Counterbore
Same as for Inside Diameter
Drilling
Bolt Circle = 1.6 mm
Bolt Hole Spacing = ± 0.8 mm
Eccentricity of Bolt Circle
≤ 2.1/2 = 0.8 mm max.
≥ 3 = 1.6 mm max.
Thickness
≤ 18 = + 3.2 mm / - 0
≥ 20 = + 4.8 mm / - 0
Length thru Hub
≤ 18 = + 3.2 mm / - 0.8 mm
≥ 20 = + 4.8 mm / - 1.6 mm
Diameter of Contact Face
1.6 mm Raised Face = ± 0.8 mm
6.35 mm Raised Face
Tongue and Groove / Male-Female
± 0.4 mm


Studs are measured parallel to the axis (L) from the first to the thread without the chamfers (points). S = free threads equals 1/3 time bolt dia

Measuring lengths of Stud Bolts

 

Hex bolts are measured from under the head to the top of de bolt


Measuring lengths of Hex bolts



Explore the World of Piping


© Werner Sölken 2008 -  
All rights reserved.
www.wermac.org uses Google Analytics


Privacy Policy


I must be old. I still believe in respect.